hitachi — Serge Voltage Prevention Circuit

SYSTEM / Electrical System SERGE VOLTAGE PREVENTION CIRCUIT 1. When the engine is stopped (key switch: OFF), current from key switch terminal M is disconnected and the battery relay is turned OFF. 2. The engine continues to rotate due to inertia force just after the key switch is turned OFF so that the alternator continues to generate electricity. 3. As the generating current cannot flow to the battery, surge voltage arises in the circuit and failures of the electronic components, such as the controller, possibly cause. In order to prevent the occurrence of surge voltage, the surge voltage prevention circuit is provided. 4.

When the alternator is generating electricity, generating current from alternator terminal L flows to monitor unit terminal #C-7. The monitor unit connects terminal #A-12 to ground. 5. Current flows through the load damp relay exciting circuit and the load damp relay is turned ON. 6. Accordingly, even if the key switch is turned OFF while the engine is rotating, battery current continues to excite the battery relay through the load damp relay. Until the alternator stops generating, the battery relay is kept ON. T2-5-16