COMPONENT OPERATION / Pump Device OUTLINE The pump device consists of transmission (11), main pump (pump 1 (1), pump 2 (2)) and pilot pump (3). The engine output is transmitted to transmission (11) via coupling (12). After being distributed by the gear, the engine power drives pump 1 (1), 2 (2) and pilot pump (3). Both reduction gear ratios of the main pump and pilot pump (3) are 1:1. Transmission (11) is lubricated with engine oil. The main pump is a bent-axis type variable displacement axial plunger pump. Pump 1 (1) and pump 2 (2) are integrated as two units in one housing. Pilot pump (3) is a gear pump.
Pump delivery pressure sensors (4, 5) and pump control pressure sensors (8, 9) are installed in order to control the pump and valve. (Refer to the Control System group in SYSTEM.) T1T1-03-01-001 10 ZX180- 3 class 9 6 7 ZX180- 3 class ZX160- 3 class 8 1 2 3 1 2 3 10 11 5 4 5 4 T1T1-03-01-002 T1V1-03-01-006 1 - Pump 1 4 - Pump 1 Delivery Pressure Sensor 7 - Torque Control Solenoid Valve 10 - Transmission 2 - Pump 2 5 - Pump 2 Delivery Pressure Sensor 8 - Pump 1 Control Pressure Sensor 11 - Coupling 3 - Pilot Pump 6 - Maximum Pump 2 Flow Rate Control Solenoid Valve 9 - Pump 2 Control Pressure Sensor 12 - Maximum Pump 1 Flow Rate Control Solenoid Valve T3-1-1 ZX160 6 7 12 -3 class 9 8