hitachi — Regulator

COMPONENT OPERATION / Pump Device Decreasing Flow Rate 1. When a control lever is returned, the flow rate control valve in signal control valve is returned and pump control pressure Pi decreases. 2. Piston (4) and spool A (3) are pushed by spring (1) so that spool A (3) is moved toward direction of the arrow. 3. Pilot pressure is also routed to the large chamber of servo piston (11). 4. Due to the difference in diameter between the large and small chambers, servo piston (11) is moved toward direction of the arrow. Therefore, the cylinder block is rotated in the minimum inclination direction and the pump delivery flow rate decreases. 5.

The movement of cylinder block is transmitted to sleeve A (2) via link (13). Sleeve A (2) is moved in the same direction as spool A (3). 6. When sleeve A (2) is moved by the same stroke as spool A (3), the open part between sleeve A (2) and spool A (3) is closed and pilot pressure to servo piston (11) is blocked. Therefore, servo piston (11) is stopped and the flow rate decreasing operation is completed.

Flow Rate (Q) Pump Control Pressure (Pi) 0 Pi Pd2 Air Bleeding Circuit Pps Dr Pd1 T1V1-03-01-005 Increase Decrease Cylinder Block Inclination 1 - Spring 4 - Piston 2 - Sleeve A 11- Servo Piston 3 - Spool A 13 - Link Pd1 -Pump 1 Delivery Pressure Pi - Pump Control Pressure Pd2 -Pump 2 Delivery Pressure Pps -Torque Control Pressure Dr - Returning to Hydraulic Oil Tank Pg - Primary Pilot Pressure (From Pilot Pump) T3-1-12 1 3 2 4 Dr Pg 11 13