hitachi — Regulator

COMPONENT OPERATION / Pump Device Control by Pilot Pressure from Flow Rate Control Solenoid Valve ZX160- 3 class : Pump 1 and Pump 2 ZX180- 3 class : Pump 2 Only Upper Limit Flow Rate Control 1. The maximum pump flow rate control solenoid valve in pump control pressure Pi circuit is activated by the signals from the main controller (MC). 2. The maximum pump flow rate control solenoid valve functions as a pressure reducing valve and pump control pressure Pi decreases. 3. Piston (4) is moved toward direction of the arrow by reduced pump control pressure Pi. 4.

Piston (4) pushes spool A (3) and spring (1), until the force acting on piston (4) by pump control pressure Pi becomes balanced with the spring (1) force, spool A (3) moves toward direction of the arrow. 5. As pump control pressure Pi has been reduced, spool A (3) is moved in a shorter distance than usual. 6. Due to the movement of spool A (3), the circuit from the large chamber of servo piston (10) is opened to the hydraulic oil tank. 7. As pilot pressure is constantly routed the small chamber of servo piston (11), servo piston (11) is moved toward direction of the arrow. Therefore, the cylinder block is rotated in the maximum inclination direction and the pump delivery flow rate increases.

8. The movement of cylinder block is transmitted to sleeve A (2) via link (13). Sleeve A (2) is moved in the same direction as spool A (3). 9. When sleeve A (2) is moved by the same stroke as spool A (3), the open part between spool A (3) and sleeve A (2) is closed and pilot pressure to the large chamber of servo piston (11) is blocked. 10. Therefore, servo piston (11) is stopped and the flow rate increasing operation is completed. 11. Accordingly, pump control pressure Pi increases in proportion to the stroke of control lever and the pump delivery flow rate increases.

However, as pump control pressure Pi is regulated, the strokes of spool A (3) and servo piston (11) are reduced so that the maximum flow rate becomes less than usual. Flow Rate (Q) Pump Control Pressure (Pi) 0 Maximum Flow Rate Upper Limit Flow Rate Flow Rate (Q) Pressure (P) 0 Pi Air Bleeding Circuit Dr T1V1-03-01-005 Increase Decrease Cylinder Block Inclination 1 - Spring 4 - Piston 2 - Sleeve A 11 - Servo Piston 3 - Spool A 13 - Link Pd1 - Pump 1 Delivery Pressure Pi - Pump Control Pressure Pd2 - Pump 2 Delivery Pressure Pps -Torque Control Pressure Dr - Returning to Hydraulic Oil Tank Pg - Primary Pilot Pressure (From Pilot Pump) T3-1-20 1 3 2 4 Dr 5 Pd1 Pps Pd2 Dr Pg 11 13 Dr Pg 13