hitachi — Solenoid Valve

COMPONENT OPERATION / Pump Device SOLENOID VALVE The torque control solenoid valve and the pump 2 flow rate limit solenoid valve are provided on the pump 2 regulator. The torque control solenoid valve supplies the torque control pressure Pps to both the pump 1 and pump 2 regulators to reduce the pump flow rate. The pump 2 flow rate limit solenoid valve reduces the pump control pressure to the pump 2 regulator so that the maximum pump flow rate is limited. The pump 1 flow rate limit solenoid valve is provided on the pump 1 regulator. The pump 1 flow rate limit solenoid valve reduces the pump control pressure to the pump 1 regulator so that the maximum pump flow rate is limited. Operation 1.

When neutral, port P is connected to the output port through the notch on the spool. 2. When the current flows to the solenoid from the MC, the solenoid is magnetized, pushing spring 1. 3. Then, spring 1 pushes the spool so that the output port is connected to port T through the notch on the spool. 4. Thereby, pressure at the output port begins to decrease. 5. Left side spool diameter (A) at the notch is larger than right side diameter (B). 6. Accordingly, until the oil pressure at the output port disappears, the external force applied onto the spool is expressed as P1 Ч B + S1 > P1 Ч A + S2. Then, the spool is move toward the right side. 7.

When the oil pressure at the output port disappears so that when P1 Ч B + S1 becomes equal to P1 Ч A + S2 (P1 Ч B + S1 = P1 Ч A + S2), the spool stops moving. P1 : Oil pressure at the output port A and B: Pressure receiving area on the spool S1 : Spring 1 force (pushing the spool toward the right side) S2 : Spring 2 force (pushing the spool toward the left side) T3-1-22