hitachi — Hydraulic Circuit

COMPONENT OPERTATION / Control Valve Positioning Circuit (2-Piece Boom) When operating boom lower and positioning, pressure oil from each pilot valve flows to the bypass shut-out valve through the shuttle valve. Therefore, the bypass shut-out valve is switched. During Single Operation: As the bypass shut-out valve is switched, the neutral circuit in 4-spool section of control valve is blocked and pressure oil from pump 1 is supplied to the positioning control valve. During Combined Operation: When operating combined operation of boom, arm or bucket and positioning, the neutral circuit in 4-spool is blocked by each spool.

Pressure oil from pump1 is supplied to the positioning control valve through the 4-spool section parallel circuit. The overload relief valve is provided in the actuator circuit (between positioning control valve and actuator) of positioning. The overload relief valve prevents surge pressure caused by external force in the actuator circuit does not exceed the set pressure when the spool is in neutral (with the control lever in neutral). T3-3-20