COMPONENT OPERTATION / Control Valve Pilot Control Circuit Pressure oil (indicated with numbers) from the pilot valve acts to the spool in control valve in order to move the spool. In the following operations, pressure oil moves the spool and acts to the switch valves as follows. During arm roll-in (4) operation, pressure oil moves the arm spool and shifts the spool in switch valve of arm anti-drift valve. During boom lower (2) operation, pressure oil moves the boom 1 spool and shifts the spool in switch valve of boom anti-drift valve. During boom lower (2) operation, divided pressure oil passes through the boom lower meter-in cut valve and shifts the bypass shut-out valve and boom 2 spool.
During auxiliary open (13) or close (14) operation, pressure oil moves the auxiliary spool and shifts the auxiliary flow combiner valve. (Only the machine equipped with the optional auxiliary flow combining system) The air bleed circuit is located on the upper section of control valve and bleeds any air trapped inside automatically. External Pilot Pressure Circuit Pressure in the main relief valve is increased by pilot pressure from solenoid valve (SG) The arm regenerative valve and arm 2 flow rate control valve are shifted by pilot pressure from solenoid valve unit (SC). The digging regenerative valve is shifted by pilot pressure from solenoid valve unit (SF).
The arm 1 flow rate control valve is shifted by pilot pressure from the arm flow rate control valve spool in signal control valve. The flow combiner valve is shifted by pilot pressure from the flow combiner valve spool in signal control valve. The bucket flow rate control valve is shifted by pressure oil from the bucket flow rate control valve spool in signal control valve. The auxiliary flow rate control valve is shifted by pilot pressure from the auxiliary flow rate control solenoid valve (optional). (Only the machine equipped with the optional auxiliary flow combining system) NOTE:
In general, the auxiliary flow combiner valve and auxiliary flow rate control valve are routed to the drain circuit. T3-3-22