hitachi — Hydraulic Circuit

COMPONENT OPERTATION / Control Valve Pilot Pressure from Auxiliary (Only machine equipped with optional auxiliary flow combining system) Auxiliary Flow Combiner Valve Pilot Pressure from Solenoid Valve Unit (SG) Main Relief Valve Flow Combiner Valve Bucket Flow Rate Control Valve Air Bleed Circuit Pilot Pressure from Flow Combiner Valve Spool in Signal Control Valve Auxiliary Flow Rate Control Valve 9 10 12 11 Pilot Pressure from Auxiliary Flow Rate Control Solenoid Valve (Only machine equipped with optional auxiliary flow combining system) Pilot Pressure from Bucket Flow Rate Control Valve Spool in Signal Control Valve 13 14 7 8 Digging Regenerative Valve 1 Pilot Pressure from Hose Rupture Valve (Arm) 1 Boom Anti-Drift Valve 2 Pilot Pressure from Solenoid Valve Unit (SF) 3 Arm Anti-Drift Valve 4 6 4 Pilot Pressure from Hose Rupture Valve (Arm) Pilot Pressure from Arm 1 Flow Rate Control Valve Spool in Signal Control Valve 3 5 Pilot Pressure from Solenoid Valve Unit (SC) Shuttle Valve Pilot Pressure from Positioning Arm 2 Flow Rate Control Valve T1V1-03-03-029 1 - Boom Raise 5 - Left Swing 9 - Travel (Left Forward) 13 - Auxiliary (Open) 2 - Boom Lower 6 - Right Swing 10 - Travel (Left Reverse) 14 - Auxiliary (Close) 3 - Arm Roll-Out 7 - Bucket Roll-In 11 - Travel (Right Forward) 4 - Arm Rool-In 8 - Bucket Roll-Out 12 - Travel (Right Reverse) Arm 1 Flow Rate Control Valve Arm Regenerative Valve Bypass Shut-Out Valve NOTE:

Yellow line: Pilot control circuit Orange line: External pilot pressure circuit T3-3-25