hitachi — Boom Lower Meter-In Cut Valve

COMPONENT OPERTATION / Control Valve BOOM LOWER METER-IN CUT VALVE The boom lower meter-in cut valve is provided in the boom lower circuit and functions with the boom flow control valve together. During boom lower operation with the front attachment above the ground, the boom flow rate control valve restricts pressure oil which flows to the boom 1 spool from pump 1 and blocks pilot pressure to the arm 2 spool. Therefore, during operation of boom lower and other actuator, the boom falls due to own weight by the regenerative circuit and uses pressure oil from the pump for other actuator so that speed of other actuator increases.

(Refer to “Hydraulic System”/ SYSTEM.) Operation (Boom Lower with Front Attachment above Ground) Operation (Jack-Up) 1. During jack-up operation, as pressure at the boom cylinder bottom side decreases, pressure in the spring chamber decreases. 2. When pressure in spring chamber becomes lower than the spring force, the boom lower meter-in cut valve moves to the right due to the spring force. 3. Therefore, as pressure oil which acts to the switch valve in boom flow rate control valve from port P17 flows to the hydraulic oil tank through the boom lower meter-in cut valve, the switch valve is returned to the original position. 4.

Pressure oil from port P17 flows to the boom 2 spool from port P 19 through the boom lower meter-in cut valve. 5. Therefore, during jack-up operation, the boom lower meter-in cut control is not operated. (Refer to “Hydraulic System”/ SYSTEM.) 1. During boom lower operation, pressure oil from the pilot pump flows to the boom 2 spool from port P19 through port P17 and boom lower meter-in cut valve. 2. Pressure oil (return oil) from the boom cylinder bottom side flows to the spring chamber in boom lower meter-in cut valve through the orifice. 3. When pressure in the spring chamber becomes larger than the spring force, the boom lower meter-in cut valve compresses the spring moves to the left. 4.

Therefore, as port P19 is connected to the hydraulic oil tank through the boom lower meter-in cut valve, the boom 2 spool is returned to the neutral position. 5. Pressure oil from port P17 flows to the switch valve in boom flow rate control valve through the spool. 6. The switch valve in boom flow rate control valve is shifted and pressure oil which flows to the boom 1 spool from pump 1 is reduced. (Refer to “Flow Control Valve”.) 7. Consequently, during combined operation of boom lower and other actuator, more pressure oil is supplied to other actuator and speed of actuator increases. T3-3-42