hitachi — Shockless Valve

COMPONENT OPERTATION / Signal Control Valve During Boom Lowering Operation (Shock Reducing Operation) 1. When the boom is lowered, the return oil from the boom raise spool in the control valve is routed to port 1. 2. As the spool blocks the oil passage between port 1 and port A, return oil cannot flow directly to port A. 3. Port 1 is connected to the spring A side in spool via inner passage 1 and to the oil chamber via inner passage 2. 4. Pressure oil in the oil chamber flows from clearance C between spool and housing and pressure in the oil chamber decreases. The spool is moved to the right by pressure acting on the spring A side.

Thereby, clearance C between the spool and housing is closed and pressure oil is blocked. 5. When clearance C is closed, pressure in the oil chamber increases and the spool moves to the left. Therefore, clearance C is opened again and pressure oil flows to port A. 6. As operations in steps (4 and 5) are repeated, pressure oil is gradually returned to port A so that the control spool returns slowly. Spring A Port 1 T1V1-03-06-004 T3-6-12 Spool Spring B Spring A Spool Port A Spring B T1V1-03-06- Spring B Port 1 Port 1