hitachi — Pump 1 and Pump 2 Flow Rate Control Valves

COMPONENT OPERTATION / Signal Control Valve PUMP 1 AND PUMP 2 FLOW RATE CONTROL VALVES The pump flow rate control valve delivers pump control pressure Pi to the pump regulator in response to pilot pressure from the pilot valve. 1. Pilot oil pressure from the pilot valve is routed into the chamber A side in either the pump 1 or pump 2 flow rate control valve after being selected by the shuttle valves in signal control valve. 2. The spool is moved to the left and primary pilot pressure flows in either port SA or SB. 3. Therefore, pressure in port SA or SB increases. 4. Pressure oil in port SA or SB acts on the spring chamber.

Thus, the spool is moved back until pressure force balances with pilot pressure force in the chamber A side so that pressure in port SA or SB stops increasing. NOTE: The pump 1 flow rate control valve operates when the boom (raise or lower), arm (roll-in or out), bucket (roll-in or out), auxiliary (machine with front attachment (secondary crushers 1 to 5, hydraulic crushers 1 to 5) attached) travel (right) and positioning functions are operated. The pump 2 flow rate control valve operates when the boom (raise), arm (roll-in or out), swing (right or left), travel (left) and auxiliary functions are operated. T3-6-14