SYSTEM / Controller Pump Control Speed Sensing Control MC calculates difference between engine speed set by the engine control dial and actual engine speed detected by ECM. MC sends the signal to the torque control solenoid valve in order to control pilot pressure oil to the pump regulator. The pump delivery flow rate is changed due to engine speed so that engine power can be used effectively. Travel Torque-Up Control When engine speed set by the engine control dial is slow, MC calculates by using the signals from travel pressure sensor and pump 1, 2 delivery pressure sensors.
MC sends the signal to the torque control solenoid valve in order to control pilot pressure oil to the pump regulator. As one pump delivery flow rate increases, both pumps delivery flow rates become equal. Consequently, mistrack is prevented during single travel operation. Pump 1 Flow Rate Limit Control (Optional) When the attachment (mainly a vibrating hammer) is used with the travel control lever in neutral, MC drives the maximum pump 1 flow rate limit control solenoid valve according to the signal from pressure sensor (auxiliary) and decreases maximum flow rate of pump 1.
Pump 1 Flow Rate Control Valve at Travel (ZX160-3 Class Only) When travel is operated during work mode “digging”, MC drives the maximum pump 1 flow rate limit control solenoid valve according to the signal from pressure sensor (travel) and decreases maximum flow rate of pump 1. Pump 2 Flow Rate Limit Control (Optional) When the attachment (mainly a breaker) is used, MC drives the maximum pump 2 flow rate limit control solenoid valve according to the signal from pressure sensor (auxiliary) and decreases maximum flow rate of pump 2.
Pump 2 Flow Rate Control Valve at Travel (ZX160-3 Class Only) When travel is operated during work mode “digging”, MC drives the maximum pump 2 flow rate limit control solenoid valve according to the signal from pressure sensor (travel) and decreases maximum flow rate of pump 2. Pump 3 Flow Rate Limit Control (Optional) As for the machine equipped with pump 3, MC drives the torque control solenoid valve according to the signal from pump 3 delivery pressure sensor, decreases delivery flow rate of pumps 1, 2, and controls pump 1, 2, 3 absorption power (pump torque) in order not to exceed engine power. T2-1-8