SYSTEM / Controller Attachment Selection (Only machines equipped with optional parts) Select digging mode and attachment mode set by Dr. ZX on this screen. When the attachment mode is selected, the monitor unit sends the signal to MC by using CAN bus line. MC drives the solenoid valve set by the attachment mode. NOTE: In attachment mode, the following five modes are set at the time of shipping from the factory. 1 - Digging 2 - Breaker 1 (HSB Breaker) T1V5-05-01-109 3 - Breaker 2 (NPK Breaker) Attachment Selection Screen 4 - Pulverizer 1 5 - Crusher 1 NOTE: The items on monitor unit and HITACHI pattern are same. When breaker 1 (HSB breaker) is selected:
(Refer to HSB Breaker Control in the Control System group.) Secondary Pilot Relief Pressure Control Valve Breaker Secondary Pilot Relief Pressure Valve MC CAN Bus Line Selector Valve From Control Valve Secondary Pilot Relief Pressure Control Solenoid Valve Selector Valve Control Solenoid Valve From Pilot Pump T1V1-02-01-063 T2-1-36 1 1 2 3 4 5 Monitor Unit HITACHI pattern Breaker1 Hydraulic Breaker1 Breaker2 Hydraulic Breaker2 Pulverizer1 Secondary Crusher1 Crusher1 Primary Crusher1