SYSTEM / Control System HP Mode Control Purpose: Slightly increases digging power such as arm roll-in operation while excavating deeply. 2200 min -1 Operation: 1. When the power mode switch is in the HP mode position and all the following conditions exist, MC sends the signals equivalent to the target engine speed to ECM by using CAN communication. 2. ECM slightly increases the engine speed set by the engine control dial in order to increase engine power. Condition: Engine Control Dial: Set at 1700 min -1 or faster. Boom Raise or Arm Roll-In Operation: Operated Average Delivery Pressure of Pumps 1 and 2: High (Reference:
25 MPa, (255 kgf/cm 2 , 3635 psi)) Engine Speed Increasing Range of Fast Idle 1700 min -1 Engine Control Dial Position Slow Idle Fast Idle NOTE: HP control can be made operable or inop- erable by Dr. ZX. Although the key is turned OFF, the setting is kept. T2-2-8