MAN — Customer Accessible Parameters

CUSTOMER ACCESSIBLE PARAMETERS CUSTOMER ACCESSIBLE PARAMETERS Customer Accessible Parameters Table 4. 26 All information subject to change without notice. Copyright © 2016 DETROIT DIESEL CORPORATION DDC-SVC-MAN-0019 Parameter Name Default Value Description OI Target Engine RPM ae 0 1000.0 RPM See table below OI Target Engine RPM ae 1 1000.0 RPM OI Target Engine RPM ae 2 1000.0 RPM OI Target Engine RPM ae 3 1000.0 RPM OI Target Engine RPM ae 4 1000.0 RPM OI Lower Limit Continuous Run -4.00°C Limit for disabling OI Thermostat Mode. OI Upper Limit Continuous Run 32.00° C OI Thermostat Max Time 0 s Maximum amount of time the engine can run in Thermostat Mode.

(0 = infinite) OI Enable Therm Ext Mode R33 and earlier: 0 disable Configures the feature of disabling OI Thermostat Mode based on ambient air temperature. R34 and later: 0 Normal OI Thermostat Mode OI Alternate Battery Run Time 0 s Sets the alternate run time for battery starts. OI Extended Mode Disable 0 enable Status of OI Extended Idle Mode. OI Continuous Batt Time Enable 0 disabled If OI has started the engine for battery voltage three consecutive times, the engine will run continuously in OI Mode. OI Variable Volt Thresh Enable 0 disabled Battery voltage threshold will be based on ambient air temperature.