Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Hydraulic pump

10 Structure, function and maintenance standard UEN00099-00 1. LS valve PA : Pump port PDP : Drain port PLP : LS control pressure output port PLS : LS pressure input port PP : Pump port PPL : Control pressure input port PSIG : LS mode selector pilot port 1. Sleeve 2. Piston 3. Spool 4. Spring 5. Sheet 6. Sleeve 7. Plug 8. Locknut Function q The LS (load sensing) valve detects the load and controls the discharge amount. q This valve controls main pump delivery (Q) according to differential pressure ( d PLS)[= PP — PLS], called the LS differential pressure (the difference between main pump pressure PP and control valve outlet port pressure PLS).

q Main pump pressure (PP), pressure (PLS) (called the LS pressure) coming from the con- trol valve output, and pressure (PSIG) (called the LS selector pressure) from the proportional solenoid valve enter this valve. q The relationship between the LS differential pressure between the main pump pressure (PP) and LS pressure (PLS) ( d PLS) [= (PP) — (PLS)] and the pump delivery (Q) changes as shown in the diagram according to LS selector current (ISIG) of the LS-EPC valve. q If (ISIG) changes from 0 to 1A, setting force the spring changes, too. As the result, the specified median of the pump delivery volume switching point changes as shown in the dia- gram.

It will change in the range of 0.27 to 1.7 MPa {in the range of 2.78 to 17.75 kg/cm 2 }. PC210, 230, 240-8 13