Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Hydraulic pump

10 Structure, function and maintenance standard UEN00099-00 Function Operation q The EPC valve consists of the proportional solenoid portion and the hydraulic valve por- tion. 1) When signal current is 0 (coil is deenergized) q When it receives signal current (i) from the controller, it generates the EPC output pres- sure in proportion to the size of the signal, and outputs it to the LS (PC) valve. q When there is no signal current flowing from the controller to coil (2), coil (2) is deenergized. q Spool (5) is pushed to the left by spring (4). q Port (P) closes and the pressurized oil from the self pressure reducing valve does not flow to the LS (PC) valve.

q The pressurized oil from the LS (PC) valve is drained to the tank via port (C) and port (T). PC210, 230, 240-8 27