Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Control valve

10 Structure, function and maintenance standard UEN00100-00 1. Suction valve (Arm out) 2. Suction valve (R.H. travel reverse) 3. Suction valve (Boom raise) 4. Suction valve (L.H. travel reverse) 5. Safety-suction valve (Bucket dump) 6. Safety-suction valve (Service 1) 7. Safety-suction valve (Service 2) 8. Safety-suction valve (Service 3) 9. 2-stage safety-suction valve (Service) 10. Safety-suction valve (Bucket curl) 11. Suction valve (L.H. travel forward) 12. Safety-suction valve (Boom lower) 13. Suction valve (R.H. travel forward) 14. Safety-suction valve (Arm in) 15. LS shuttle valve (Arm) 16. LS shuttle valve (R.H. travel) 17. LS select valve 18. LS shuttle valve (Boom) 19.

LS shuttle valve (L.H. travel) 20. LS shuttle valve (Bucket) 21. LS shuttle valve (Service 1) 22. LS shuttle valve (Service 2) 23. LS shuttle valve (Service 3) 24. LS check valve 25. Pressure relief plug Unit: mm PC210, 230, 240-8 9 No. Check item Criteria Remedy 26 Suction valve spring Standard size Repair limit If damaged or deformed, replace spring. Free length x Outside diame- ter Installed length Installation load Free length Installation load 46.8 x 7.5 40.6 5.5 N {0.56 kg} — 4.4 N {0.45 kg} 27 Check valve spring 11.5 x 4.6 8.5 1.5 N {0.15 kg} — 1.2 N {0.12 kg}