UEN00100-00 10 Structure, function and maintenance standard Basic principle 1 1. Pump swash plate angle control q The pump swash plate angle (pump delivery) is controlled so that LS differential pressure ( d PLS) (the difference between pump pres- sure PP and control valve outlet port LS pres- sure PLS) (load pressure of actuator) is constant. q The pump swash plate angle shifts toward the maximum position if LS differential pressure ( d PLS) is lower than the set pressure of the LS valve (when the actuator load pressure is high). q If it becomes higher than the set pressure (when the actuator load pressure is low), the pump swash plate angle shifts toward the mini- mum position.
q [LS differential pressure ( d PLS) = Pump dis- charge pressure (PP) — LS pressure (PLS)] LS differential pressure ( d PLS) and pump swash plate angle a For details of functions, see the “Hydraulic pump“ paragraph. 16 PC210, 230, 240-8