Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Functions and operation by valve

UEN00100-00 10 Structure, function and maintenance standard 2. When travelling Operation q If the right travel lever is set in the reverse (or forward) direction, pilot pressure from the PPC valve presses spool (7) to the left (or right). q Maximum stroke of the spool is limited to (st1) for the amount of movement (st2) of piston (8) to the right. q Spool (7) pushes piston (3) to close orifice (5) and shut off stroke regulation signal chamber (a) and the drain circuit of the travel PPC valve. q At this time, the right travel reverse (or forward) lever is set, PPC pressure is applied through orifice (6) of piston (4) to the left end of piston (8) to push piston (8) to the right.

q When operated for boom raising (or arm IN, OUT, bucket curl, dump), spool (1) moves to the left. 44 PC210, 230, 240-8