Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Travel motor

10 Structure, function and maintenance standard UEN00160-00 2) At high peed (motor swash plate angle at minimum) q As the solenoid valve is energized, the pilot pressurized oil from the self pressure reducing valve flows to port (P). q Regulator valve (9) is pushed to the left. q The pressurized oil from the control valve passes through passage (d) in regulator valve (9) and enters regulator piston (15). q Regulator piston (15) is pushed to the right. q Rocker cam (4) is inclined in the minimum swash plate angle direction. The motor capac- ity becomes minimum, turning on the high speed travel. PC210, 230, 240-8 19