10 Structure, function and maintenance standard UEN00160-00 P: From self pressure reducing valve P1: To service valve P2: To service valve T: To tank 1. Spool 2. Piston 3. Lever 4. Plate 5. Retainer 6. Body Unit: mm No. Remedy 7 If damaged or deformed, replace spring. 8 PC210, 230, 240-8 47 Check item Criteria Centering spring Standard size Repair limit Free length x Outside diameter Installation length Installation load Free length Installation load 33.9 x 15.3 28.4 125 N {12.7 kg} — 100 N {10.2 kg} Metering spring 22.7 x 8.10 22.0 16.7 N {1.70 kg} — 13.3 N {1.36 kg}