10 Structure, function and maintenance standard UEN00103-00 1) Auto-warm-up function q After the engine is started, if the engine coolant temperature is low, the engine speed is raised automatically to warm up the engine. Coolant temperature: Below 30°C Engine speed: Max. 1,200 rpm Engine speed: 1,200 rpm Operating condition (All of following conditions) Operated Reset Engine speed: Any level 2) Overheat prevention function q This function reduces the pump load and engine speed when coolant or hydraulic oil temperature is too high to protect the engine and hydraulic components from overheating.
q This function starts when coolant temperature reaches 100°C or hydraulic oil temperature reaches 95°C. PC210, 230, 240-8 21 Resetting condition (Any one of following conditions) Auto Coolant temperature: Min. 30°C Auto-warm-up operation time: Min. 10 minutes Manual Fuel control dial: Kept at 70% of full level or above for 3 sec. or longer Operating condition Operation/Remedy Resetting condition Coolant temperature: Min. 105°C or Hydraulic oil temperature: Min. 105°C Working mode: Any mode Engine speed: Low idle Monitor alarm lamp: Lights up Alarm buzzer: Sounds Coolant temperature, hydraulic oil temperature: Below 105°C Fuel control dial: Return to low idle position once.
Under above condition, controller is set to condi- tion before operation of function. (Manual reset) Operating condition Operation/Remedy Resetting condition Coolant temperature: Min. 102°C or Hydraulic oil temperature: Min. 102° Working mode: P, E, B, or L mode Engine speed: Kept as is. Monitor alarm lamp: Lights up Reduce pump delivery. Coolant temperature, hydraulic oil temperature: Below 102°C Under above condition, controller is set to condi- tion before operation of function. (Automatic reset) Operating condition Operation/Remedy Resetting condition Coolant temperature: Min. 100°C or Hydraulic oil temperature: Min. 100°C Working mode: P or E mode Engine speed: Kept as is.
Reduce pump delivery. Coolant temperature, hydraulic oil temperature: Below 100°C Under above condition, controller is set to condi- tion before operation of function. (Automatic reset) Operating condition Operation/Remedy Resetting condition Hydraulic oil temperature: Min. 95°C Working mode: Travel Engine speed: Kept as is. Lower travel speed. Hydraulic oil temperature: Below 95°C Under above condition, controller is set to condi- tion before operation of function. (Automatic reset)