Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Monitor system

UEN00103-00 10 Structure, function and maintenance standard F3 : Selects (highlights) an item one down. F4 : Selects (highlights) an item one up. F5 : Returns to the breaker/attachment setting screen. F6 : Switches to the setting screen for the selected (highlighted) item. F3 : Selects (highlights) an item one down. F4 : Selects (highlights) an item one up. F5 : Returns to the breaker setting menu screen. F6 : Switches to the flow rate level setting screen for the selected (highlighted) item. 1. Attachment setting selection screen q On this screen, you can allocate one of two set flow rates as a flow rate in attach- ment mode.

q On the flow rate level setting screen, change the set flow rate. q The ATT symbol is displayed before items specified to attachment mode. a The defaults of both flow rates are 430 l / min. F3 : Decreases the flow rate. F4 : Increases the flow rate. F5 : Returns to the flow rate setting screen without changing the flow rate. F6 : Returns to the flow rate setting screen after specifying the flow rate. F3 : Selects (highlights) an item one down. F4 : Selects (highlights) an item one up. F5 : Returns to the attachment setting menu. F6 : Specifies the selected (highlighted) item as a flow rate in attachment mode.

Flow level Flow ( l /min) Remarks 8 430 Default 7 350 q Selecting “No attachment” disables selec- tion of attachment mode on the working mode selection screen. 6 250 5 170 4 140 2. Attachment flow rate setting screen 3 115 q On this screen, you can specify a flow rate. 2 90 1 30 q The ATT symbol is displayed before items specified to attachment mode. 50 PC210, 230, 240-8