UEN00230-00 30 Testing and adjusting * Gauge changing work: Change hoses of gauges [3] and [4]. * Gauge changing work: Change [3] and [4] to 60K and change hoses of [3], [4], and [5]. 20 PC210, 230, 240-8 No. Check item Checking condition [1] [2] [3a] [4a] [5] Good Bad 600K 600K 600K 600K 60K Fuel control dial Work- ing mode Left knob switch Operation of work equipment F pump main R pump main F pump servo R pump servo Control 8 Servo piston MAX P OFF Arm out relief H1 H1 H2 H2 — Standard value Checked oil pressure Unit Standard value for new machine Service limit value H (Servo control pressure) — H1 : H2 = 1 : 0.6 (Oil pressure ratio) No.

Check item Checking condition [1] [2] [3b] [4b] [5a] Good Bad 600K 600K 60K 60K 60K Fuel control dial Work- ing mode Left knob switch Operation of work equipment F pump main R pump main PC-EPC (F) PC-EPC (R) LS-EPC 9 PC-EPC (F) valve PC-EPC (R) valve MIN P OFF All levers in neutral — — J1 J1 — MAX — — J2 J2 — E — — J3 J3 — L — — J4 J4 — B — — J5 J5 — 10 LS-EPC valve P Travel speed: Lo travel lever in neutral — — — — K1 Travel speed: Mi Travel lever operated — — — — K2 Travel speed: Hi Travel lever operated — — — — K3 Standard value Checked oil pressure Unit Standard value for new machine Service limit value J1 (PC-EPC valve output pressure 1) MPa {kg/cm2} Approx. 2.9 {Approx.

30} J2 (PC-EPC valve output pressure 2) Approx. 0.7 {Approx. 7} J3 (PC-EPC valve output pressure 3) Approx. 0.78 {Approx. 8} J4 (PC-EPC valve output pressure 4) 2.01 {21} J5 (PC-EPC valve output pressure 5) Approx. 1.57 {Approx. 16} K1 (LS-EPC valve output pressure 1) Approx. 2.45 {Approx. 25} K2 (LS-EPC valve output pressure 2) Approx. 1.7 {Approx. 17.5} K3 (LS-EPC valve output pressure 3) 0 {0}