40 Troubleshooting UEN00240-00 Failure code [989N00] Engine Controller Lock Caution 3 1 Failure code [AA10NX] Air Cleaner Clogging 1 PC210, 230, 240-8 15 User code Failure code Trouble Engine controller lock caution 3 (Machine monitor system) — 989N00 Contents of trouble • Engine controller lock is detected (Factor 3). Action of machine monitor • Tries automatic resetting. • If cause of failure disappears, system resets itself. Problem that appears on machine Related infor- mation • Method of reproducing failure code: Failure code is not reproduced since system is reset automati- cally.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective engine controller If this failure code is displayed repeatedly, engine controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) User code Failure code Trouble Air cleaner clogging (Machine monitor system) — AA10NX Contents of trouble • While engine was running, signal circuit of air cleaner clogging switch detected clogging of air cleaner (sensor contact opened). Action of machine monitor • Displays air cleaner clogging monitor on machine monitor. • If cause of failure disappears, system resets itself.
Problem that appears on machine • If machine is operated as it is, engine may be damaged. Related infor- mation • Condition of air cleaner clogging switch signal can be checked with monitoring function. (Code: 04501 Monitor input 2) • Method of reproducing failure code: Start engine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Clogging of air cleaner (when system is normal) Air cleaner may be clogged. Check it for clogging and then clean or replace if clogged. 2 Defective air cleaner clog- ging monitor system If cause 1 is not detected, air cleaner clogging monitor system may be defective.
Carry out troubleshooting for "E-7 Caution item flashes while engine is running" in E-mode.