UEN00240-00 40 Troubleshooting Failure code [CA131] Throttle Sensor High Error 1 26 PC210, 230, 240-8 User code Failure code Trouble Throttle sensor high error (Engine controller system) E14 CA131 Contents of trouble • Signal circuit of fuel control dial detected high voltage. Action of controller • If trouble occurs while starting switch is in ON position, controller fixes voltage value to level just before detection of trouble and continues operation. • If starting switch is turned ON while voltage is abnormally high, controller continues operation with voltage at 100% value. Problem that appears on machine • Engine speed cannot be controlled with fuel control dial.
Related infor- mation • Signal voltage of fuel control dial can be checked with monitoring function. (Code: 03000 Fuel con- trol dial voltage) • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective throttle sensor power supply system If failure code [CA2185] is also indicated, carry out troubleshooting for it first. 2 Defective fuel control dial a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. P20 Voltage Between (1) – (3) Power supply 4.75 – 5.25 V Voltage is measured with wiring harness connected.
Accordingly, if voltage is abnormal, check wiring harness and controller, too, for another cause of trouble, and then judge. 3 Hot short (Short circuit with 5 V/24 V circuit) in wiring har- ness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between CE02 (female) (9) – P20 (female) (2) Voltage Max. 1 V 4 Short circuit in wiring har- ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE02 (female) (9) – P20 (female) (2) and between CE02 (female) (22) – P20 (female) (1) Resis- tance Min.
100 kz 5 Defective wiring harness connector Connecting parts between fuel control dial – machine wiring har- ness – engine controller may be defective. Check them directly. • Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 6 Defective engine controller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. CE02 Voltage Between (22) – (23) Power supply 4.75 – 5.25 V