UEN00240-00 40 Troubleshooting Failure code [CA155] Chg Air Temp High Speed Derate 1 38 PC210, 230, 240-8 User code Failure code Trouble Charge air temperature high speed derate (Engine controller system) E11 CA155 Contents of trouble • Temperature signal of boost pressure/temperature sensor exceeded control upper temperature limit. Action of controller • Limits output and continues operation. Problem that appears on machine • Engine output lowers. • Engine stops. Related infor- mation • Boost temperature can be checked with monitoring function. (Code: 18500 Boost temperature) • Method of reproducing failure code:
Start engine Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Lowering of cooling perfor- mance of aftercooler Cooling performance of aftercooler may be low. Check following points directly. • Looseness and breakage of fan belt. • Insufficiency of cooling air • Clogging of aftercooler fins 2 Abnormal rise of turbo- charger outlet temperature Outlet temperature of turbocharger may be abnormally high. Check related parts directly. 3 Defective engine controller If causes 1 – 2 are not detected, engine controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)