Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [CA222] Ambient Press Sens Low Error

UEN00240-00 40 Troubleshooting Failure code [CA222] Ambient Press Sens Low Error 1 44 PC210, 230, 240-8 User code Failure code Trouble Ambient pressure sensor low error (Engine controller system) E11 CA222 Contents of trouble • Low voltage was detected in signal circuit of ambient pressure sensor. Action of controller • Fixes ambient pressure value and continues operation. Problem that appears on machine • Engine does not start easily. • Engine output lowers. Related infor- mation • Signal voltage of ambient pressure sensor can be checked with monitoring function. (Code: 37401 Ambient pressure sensor voltage • Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor power sup- ply 1 system If failure code [CA352] is also indicated, carry out troubleshooting for it first. 2 Defective ambient pressure sensor a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. AMBAIR PRESURE Voltage Between (1) – (2) Power supply 4.75 – 5.25V Voltage is measured with wiring harness connected. Accordingly, if voltage is abnormal, check wiring harness and controller, too, for another cause of trouble, and then judge.

3 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE01 (female) (3) – AMBAIR PRESSURE (female) (3) Resis- tance Min. 100 kz 4 Short circuit in wiring har- ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE01 (female) (3) – AMBAIR PRESSURE (female) (3) and between CE01 (female) (38) – JC03 – AMBAIR PRESSURE (female) (2) Resis- tance Min.

100 kz 5 Defective wiring harness connector Connecting parts between ambient pressure sensor – engine wiring harness – engine controller may be defective. Check them directly. • Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 6 Defective engine controller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. CE01 Voltage Between (33) – (38) Voltage 4.75 – 5.25 V