UEN00240-00 40 Troubleshooting Failure code [CA322] Inj #1 (L#1) Open/Short Error 1 52 PC210, 230, 240-8 User code Failure code Trouble Injector #1 (L#1) open/short circuit error (Engine controller system) E11 CA322 Contents of trouble • Opening or short circuit was detected in drive circuit of No. 1 injector. Action of controller • None in particular. Problem that appears on machine • Combustion becomes irregular or engine hunts. • Engine output lowers. Related infor- mation • Method of reproducing failure code: Start engine.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective engine controller If following failure codes are also displayed, trouble is in engine con- troller. [CA322], [CA324], [CA331] 2 Defective No. 1 injector a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. INJ CYL 1 (male) Resistance Between (1) – (2) Max. 2 z Between (1) – chassis ground Min. 100 kz 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
Wiring harness between CE01 (female) (45) – INJ CYL 1 (female) (1) Resis- tance Max. 2 z Wiring harness between CE01 (female) (53) – INJ CYL 1 (female) (2) Resis- tance Max. 2 z 4 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE01 (female) (45) – INJ CYL 1 (female) (1) Resis- tance Max. 2 z 5 Short circuit in wiring harness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
Wiring harness between CE01 (female) (45) – each of CE01 (female) pins (With all wiring harness connectors disconnected) Resis- tance Min. 100 kz Wiring harness between CE01 (female) (53) – each of CE01 (female) pins (With all wiring harness connectors disconnected) Resis- tance Min. 100 kz 6 Defective wiring harness connector Connecting parts between No. 1 injector – engine wiring harness – engine controller may be defective. Check them directly.
• Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 7 Defective engine controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. CE01 (female) Resistance Between (45) – (53) Max. 2 z Between (45) – chassis ground Min. 100 kz