Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [CA351] Injectors Drive Circuit Error

UEN00241-00 40 Troubleshooting Failure code [CA351] Injectors Drive Circuit Error 1 4 PC210, 230, 240-8 User code Failure code Trouble Injectors Drive Circuit Error (Engine controller system) E10 CA351 Contents of trouble • There is error in drive power circuit of injector. Action of controller • Limits output and continues operation. Problem that appears on machine • Exhaust gas becomes black. • Combustion becomes irregular. • Engine output lowers. • Engine cannot be started. Related infor- mation • Method of reproducing failure code: Start engine.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defect in related system If another failure code is displayed, carry out troubleshooting for it. 2 Defective fuse No. 19 If fuse is broken, circuit probably has ground fault. 3 Defective relay for engine controller power supply a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Replace relay (R23, R24) for engine controller with another relay and perform reproducing operation. If "E" of failure code goes off at this time, replaced relay is defective.

4 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between F01-19 – R23, R24 (female) (3) Resis- tance Max. 0.5 z Wiring harness between R23, R24 (female) (5) – CE03 (female) (3) Resis- tance Max. 0.5 z Wiring harness between CE03 (female) (1) – chassis ground (T12) Resis- tance Max. 10 z 5 Defective engine controller If causes 1 – 4 are not detected, engine controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)