Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [CA352] Sens Supply 1 Volt Low Error

UEN00241-00 40 Troubleshooting Failure code [CA352] Sens Supply 1 Volt Low Error 1 6 PC210, 230, 240-8 User code Failure code Trouble Sensor power supply 1 voltage low error (Engine controller system) E15 CA352 Contents of trouble • Low voltage was detected in sensor power supply 1 circuit. Action of controller • Fixes ambient pressure value and continues operation. Problem that appears on machine • Engine does not start easily. • Engine output lowers. Related infor- mation • Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor or wiring harness a Disconnect connector with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Disconnect sensor and wiring harness at right in order and carry out operation to reproduce trouble. If "E" of failure code goes off when sensor or wiring harness is disconnected, that sensor or wiring har- ness is defective.

Ambient pressure sensor AMBAIR PRESURE Engine wiring har- ness CE01 2 Defective wiring harness connector Connecting parts between ambient pressure sensor – engine wiring harness – engine controller may be defective. Check them directly. • Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 3 Defective engine controller If causes 1 – 2 are not detected, engine controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)