Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [CA386] Sens Supply 1 Volt High Error

UEN00241-00 40 Troubleshooting Failure code [CA386] Sens Supply 1 Volt High Error 1 Circuit diagram related to sensor power supply 1 8 PC210, 230, 240-8 User code Failure code Trouble Sensor power supply 1 voltage high error (Engine controller system) E15 CA386 Contents of • trouble High voltage was detected in sensor power supply 1 circuit. Action of • controller Fixes ambient pressure value and continues operation. Problem that • appears on • machine Engine does not start easily. Engine output lowers. Related infor- • mation Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard 1 value in normal state 2 Cause Standard value in normal state/Remarks on troubleshooting Defective wiring harness connector Connecting parts between ambient pressure sensor – engine wiring harness – engine controller may be defective. Check them directly. • Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation Defective engine controller If cause 1 is not detected, engine controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)