UEN00241-00 40 Troubleshooting Failure code [CA428] Water in Fuel Sensor High Error 1 10 PC210, 230, 240-8 User code Failure code Trouble Water-in-fuel sensor high error (Engine controller system) E15 CA428 Contents of trouble • High voltage was detected in signal circuit of water-in-fuel sensor. Action of controller • None in particular. Problem that appears on machine • Water separator monitor does not display normally. Related infor- mation • Condition water-in-fuel sensor signal can be checked with monitoring function. (Code: 18800 Condi- tion of WIF sensor) • Method of reproducing failure code: Turn starting switch ON.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective water-in-fuel sen- sor a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. P47 (female) Resistance Between (1) – (2) Max. 10 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE01 (female) (14) – P47 (male) (1) Resis- tance Max. 10 z Wiring harness between CE01 (female) (47) – JC02 – P47 (male) (2) Resis- tance Max.
10 z 3 Short circuit in wiring har- ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE01 (female) (14) – each of CE01 (female) pins (With all wiring harness connectors disconnected) Resis- tance Min. 100 kz 4 Defective wiring harness connector Connecting parts between water-in-fuel sensor – engine wiring har- ness – engine controller may be defective. Check them directly.
• Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 5 Defective engine controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. CE01 (female) Resistance Between (14) – (47) Max. 10 z