UEN00241-00 40 Troubleshooting Failure code [CA442] Battery Voltage High Error 1 18 PC210, 230, 240-8 User code Failure code Trouble Battery voltage high error (Engine controller system) E10 CA442 Contents of trouble • There is high voltage (36 V or higher) in controller power supply circuit. Action of controller • None in particular. Problem that appears on machine • Engine may stop. Related infor- mation • Method of reproducing failure code: Turn starting switch ON.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective battery voltage a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Battery Voltage Between (+) – (–) terminals Max. 32 V 2 Defective alternator a Prepare with starting switch OFF, then start engine and carry out troubleshooting. E12 (male) Engine speed Voltage Between (1) – chas- sis ground Medium or higher 27.5 – 29.5 V 3 Defective engine controller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. CE03 (female) Voltage Between (3) – (1) Max. 32 V