Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [CA2311] IMV Solenoid Error

UEN00241-00 40 Troubleshooting Failure code [CA2311] IMV Solenoid Error 1 42 PC210, 230, 240-8 User code Failure code Trouble IMV solenoid error (Engine controller system) E11 CA2311 Contents of trouble • Resistance of supply pump actuator circuit is abnormally high or low. Action of controller • None in particular. Problem that appears on machine • Engine output lowers. Related infor- mation • Method of reproducing failure code: Start engine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defect in related system If another failure code is displayed, carry out troubleshooting for it.

2 Defective supply pump actu- ator a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. CP3 PUMP REGULATOR (male) Resistance Between (1) – (2) Max. 5 z Between (1) – chassis ground Min. 100 kz 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE01 (female) (2) – CP3 PUMP REGULATOR (female) (1) Resis- tance Max. 5 z Wiring harness between CE01 (female) (32) – CP3 PUMP REGULATOR (female) (2) Resis- tance Max.

5 z 4 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE01 (female) (2) – CP3 PUMP REGULATOR (female) (1) Resis- tance Min. 100 kz 5 Defective wiring harness connector Connecting parts between supply pump actuator – engine wiring harness – engine controller may be defective. Check them directly.

• Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 6 Defective engine controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. CE01 (female) Resistance Between (2) – (32) Max. 5 z Between (2) – chassis ground Min. 100 kz