Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [CA2555] Grid Htr Relay Volt High Error

UEN00241-00 40 Troubleshooting Failure code [CA2555] Grid Htr Relay Volt High Error 1 44 PC210, 230, 240-8 User code Failure code Trouble Grid heater relay volt high error (Engine controller system) E15 CA2555 Contents of trouble • Disconnection was detected in drive circuit of intake air heater relay. Action of controller • None in particular. Problem that appears on machine • Intake air heater does not work (Engine does not start easily and exhaust gas becomes white at low temperature). Related infor- mation • Method of reproducing failure code: Turn starting switch ON when engine coolant temperature is below –4°C.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective automatic pre- heater relay (Internal discon- nection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. (Troubleshooting for relay unit) R18 (male) Resistance Between (1) – (2) 300 – 600 z a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. (Troubleshooting by replacement) Replace automatic preheater relay (R18)) with another relay and perform reproducing operation. If "E" of failure code goes off at this time, replaced relay is defective.

2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE02 (female) (40) – R18 (female) (1) Resis- tance Max. 10 z Wiring harness between CE02 (female) (42) – R18 (female) (2) Resis- tance Max. 10 z 3 Short circuit in wiring har- ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE02 (female) (40) – each of CE02 (female) pins (With R18 dis- connected) Resis- tance Min.

100 kz 4 Defective wiring harness connector Connecting parts between automatic preheater relay – machine wir- ing harness – engine controller may be defective. Check them directly. • Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 5 Defective engine controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. CE02 (female) Resistance Between (40) – (42) 300 – 600 z