Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [D19JKZ] Personal Code Relay Abnormality

UEN00241-00 40 Troubleshooting Failure code [D19JKZ] Personal Code Relay Abnormality 1 48 PC210, 230, 240-8 User code Failure code Trouble Personal code relay abnormality (KOMTRAX system in machine monitor) E01 D19JKZ Contents of trouble • Disconnection or short circuit was detected in personal code relay circuit. Action of controller • None in particular (when disconnection is detected). • Turns output to personal code relay OFF (when short circuit is detected). • If cause of failure disappears, system resets itself (when disconnection is detected). • Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF.

Problem that appears on machine Related infor- mation • Method of reproducing failure code: Turn starting switch ON (Disconnection). Trouble cannot be reproduced on machine (Short circuit). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse No. 3 If fuse is broken, circuit probably has ground fault (See cause 4). 2 Defective personal code relay (Internal disconnection or short circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

(Troubleshooting for relay unit) R07 (male) Resistance Between (1) – (2) (300 – 600 z) a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. (Troubleshooting by replacement) Replace personal code relay (R07)) with another relay and perform reproducing operation. If "E" of failure code goes off at this time, replaced relay is defective. 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between F01 (3) – R07 (female) (1) Resis- tance Max.

1 z Wiring harness between R07 (female) (2) – CM01 (female) (6) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between F01 (3) – R07 (female) (1) Resis- tance Min. 1 Mz Wiring harness between R07 (female) (2) – CM01 (female) (6) Resis- tance Min. 1 Mz 5 Defective machine monitor (KOMTRAX section) If causes 1 – 4 are not detected, machine monitor (KOMTRAX) may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)