Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DA29KQ] Model Selection Abnormality

UEN00241-00 40 Troubleshooting Failure code [DA29KQ] Model Selection Abnormality 1 PC210, 210LC-8 58 PC210, 230, 240-8 User code Failure code Trouble Model selection abnormality (Pump controller system) — DA29KQ Contents of trouble • Model code signal for model which is not registered in controller is input. Action of controller • Changes input model code to code of default model (PC210) and continues control. • Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF. Problem that appears on machine • Since control is carried out on assumption that model is PC210, no particular problem occur.

Related infor- mation • Model code of pump controller can be checked with monitoring function. (Code: 00200 Controller model code) • Condition of model selection signal can be checked with monitoring function. (Code: 02201 Switch input 2) • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective model selection connector (Internal discon- nection or short circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. S30 (female) Resistance Between (1), (2), (4), (7) – (8) Min. 1 Mz Between (3) – (8) Max.

1 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C01 (female) (77) – S30 (male) (3) Resis- tance Max. 1 z Wiring harness between S30 (male) (8) – J05 – chassis ground (T07) Resis- tance Max. 1 z 3 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. iring harness between C01 (female) (40) – S30 (male) (1) Resis- tance Min. 1 Mz Wiring harness between C01 (female) (21) – S30 (male) (2) Resis- tance Min.

1 Mz Wiring harness between C01 (female) (58) – S30 (male) (4) Resis- tance Min. 1 Mz Wiring harness between C01 (female) (39) – S30 (male) (7) Resis- tance Min. 1 Mz 4 Defective pump controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C01 (female) Resistance Between (21), (39), (40), (68) – chassis ground Min. 1 Mz Between (77) – chassis ground Max. 1 z