Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DA2RMC] CAN Discon (Pump Con Detected)

UEN00242-00 40 Troubleshooting Troubleshooting by failure code (Display of code), Part 3 1 Failure code [DA2RMC] CAN Discon (Pump Con Detected) 1 4 PC210, 230, 240-8 User code Failure code Trouble CAN disconnection (Pump controller detected) (Pump controller system) E0E DA2RMC Contents of trouble • Pump controller detected communication error in CAN communication circuit between machine mon- itor and engine controller. Action of controller • Continues operation with information of CAN communication just before detection of error. • If cause of failure disappears, system resets itself.

Problem that appears on machine • Information may not transmitted normally by CAN communication and machine may not operate nor- mally. (Trouble phenomenon depends on failed section.) Related infor- mation • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

Wiring harness between CM02 (female) (8), (9) – C01 (female) (45), – CE02 (female) (46), – K02 (female) (A) Resis- tance Max. 1 z Wiring harness between CM02 (female) (10) – C01 (female) (64), – CE02 (female) (47), – K02 (female) (B) Resis- tance Max. 1 z 2 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CM02 (female) (8), (9) – C01 (female) (45), – CE02 (female) (46), – K02 (female) (A), – N08 (male) (3) Resis- tance Min.

1 Mz Wiring harness between CM02 (female) (10) – C01 (female) (64), – CE02 (female) (47), – K02 (female) (B), – N08 (male) (10) Resis- tance Min. 1 Mz 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between CM02 (female) (8), (9) – C01 (female) (45), – CE02 (female) (46), – K02 (female) (A), – N08 (male) (3) Voltage Max. 5.5 V Wiring harness between CM02 (female) (10) – C01 (female) (64), – CE02 (female) (47), – K02 (female) (B), – N08 (male) (10) Voltage Max.

5.5 V 4 Defective CAN terminal resistance (Internal short cir- cuit or disconnection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. K02 (male) Resistance Between (A) – (B) 120 ± 12 z 5 Defective pump controller If causes 1 – 4 are not detected, pump controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)