UEN00242-00 40 Troubleshooting Failure code [DAFGMC] GPS Module Error 1 6 PC210, 230, 240-8 User code Failure code Trouble GPS module operation error (KOMTRAX system in machine monitor) — DAFGMC Contents of trouble • Position data is not sent from GPS module (in machine monitor) to KOMTRAX communication MODEM in 50 seconds after KOMTRAX is started. Action of machine monitor • None in particular. • If cause of failure disappears, system resets itself. Problem that appears on machine Related infor- mation • Method of reproducing failure code: Turn starting switch ON (At least 50 seconds after starting switch is turned ON).
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective machine monitor GPS module of machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)