UEN00242-00 40 Troubleshooting Failure code [DGH2KB] Hydr Oil Sensor Short 1 Circuit diagram related to hydraulic oil temperature sensor 10 PC210, 230, 240-8 User code Failure code Trouble Hydraulic oil temperature sensor short (Pump controller system) — DGH2KB Contents of trouble • Ground fault was detected in hydraulic oil temperature sensor circuit. Action of controller • Fixes hydraulic oil temperature value at 40°C and continues operation. • If cause of failure disappears, system resets itself. Problem that appears on machine • While hydraulic oil temperature rises normally, hydraulic oil temperature gauge does not move from top of white range (bottom of green range).
Related infor mation • Signal voltage of hydraulic oil temperature sensor can be checked with monitoring function. - (Code: 04402 Hydraulic oil temperature sensor voltage) • Method of reproducing failure code: Start engine. Possible cause and standard value in norm state Cause Defective hydraulic oil tem- 1 perature sensor (Internal dis- connection or short circuit) s Ground fault in wiring har- al 2 ness (Short circuit with GND circuit) 3 Defective pump controller Standard value in normal state/Remarks on troubleshooting a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
P22 (male) Resistance Between (1) – (2) 3.5 – 90 kz Between (2) – chassis ground Min. 1 Mz a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C01 (female) (29) – P22 (female) (2) Resis- tance Min. 1 Mz a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C01 (female) Resistance Between (29) – (46) 3.5 – 90 kz Between (29) – chassis ground Min. 1 Mz