Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DHPAMA] F Pump Press Sensor Abnormality

UEN00242-00 40 Troubleshooting Failure code [DHPAMA] F Pump Press Sensor Abnormality 1 12 PC210, 230, 240-8 User code Failure code Trouble F pump pressure sensor abnormality (Pump controller system) — DHPAMA Contents of trouble • Signal voltage of F pump pressure sensor circuit is below 0.3 V or above 4.5 V. Action of controller • Fixes F pump pressure at 0 MPa {0 kg/cm2} and continues control. • If cause of failure disappears, system resets itself. Problem that appears on machine • Automatic gear shifting function does not work. • Straight travel performance or steering performance lowers.

Related infor- mation a If 5V circuit (3) and ground circuit (1) of pressure sensor are connected inversely, pressure sensor will be broken. Accordingly, take extreme care when checking. • F pump pressure can be checked with monitoring function. (Code: 01100 F pump pressure) • Method of reproducing failure code: Turn starting switch ON or start engine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective 5V sensor power supply 1 system a If failure code [DA25KP] is also displayed, carry out trouble- shooting for it first.

2 Defective F pump pressure sensor (Internal defect) a Prepare with starting switch OFF, then turn starting switch ON or start engine and carry out troubleshooting in each case. P25 Voltage Between (3) – (1) Power supply 4.5 – 5.5 V Between (2) – (1) Signal 0.3 – 4.5 V If voltage is abnormal, replace F pump pressure sensor with R pump pressure sensor and check failure code. (If "E" of failure code goes off at this time, F pump pressure sensor is defective.) 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

Wiring harness between C01 (female) (18) – P25 (female) (1) Resis- tance Max. 1 z Wiring harness between C01 (female) (49) – P25 (female) (2) Resis- tance Max. 1 z Wiring harness between C01 (female) (9) – J06 – P25 (female) (3) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C01 (female) (49) – P25 (female) (2) Resis- tance Min. 1 Mz 5 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.

Wiring harness between C01 (female) (49) – P25 (female) (2) Voltage Max. 1 V 6 Defective pump controller If causes 1 – 5 are not detected, pump controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)