Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DHS3MA] Arm Curl PPC Press Sensor Abnormality

UEN00242-00 40 Troubleshooting Failure code [DHS3MA] Arm Curl PPC Press Sensor Abnormality 1 16 PC210, 230, 240-8 User code Failure code Trouble Arm curl PPC pressure sensor abnormality (Pump controller system) — DHS3MA Contents of trouble • Signal voltage of arm curl PPC pressure sensor circuit is below 0.3 V or above 4.5 V. Action of controller • Fixes arm curl PPC pressure at 0 MPa {0 kg/cm2} and continues control. • If cause of failure disappears, system resets itself. Problem that appears on machine • Automatic decelerator cannot be reset. • Arm curl performance lowers.

Related infor- mation a If 5V circuit (3) and ground circuit (1) of pressure sensor are connected inversely, pressure sensor will be broken. Accordingly, take extreme care when checking. • Arm curl PPC pressure can be checked with monitoring function. (Code: 07200 Arm curl PPC pressure) • Method of reproducing failure code: Turn starting switch ON or start engine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective 5V sensor power supply 1 system If failure code [DA25KP] is also displayed, carry out troubleshooting for it first.

2 Defective arm curl PPC pres- sure sensor (Internal defect) a Prepare with starting switch OFF, then turn starting switch ON or start engine and carry out troubleshooting in each case. P04 Voltage Between (3) – (1) Power supply 4.5 – 5.5 V Between (2) – (1) Signal 0.3 – 4.5 V If voltage is abnormal, replace arm curl PPC pressure sensor with another PPC pressure sensor and check failure code. (If "E" of fail- ure code goes off at this time, arm curl PPC pressure sensor is defective.) 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

Wiring harness between C01 (female) (18) – P04 (female) (1) Resis- tance Max. 1 z Wiring harness between C01 (female) (17) – P04 (female) (2) Resis- tance Max. 1 z Wiring harness between C01 (female) (9) – J06 – P04 (female) (3) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C01 (female) (17) – P04 (female) (2) Resis- tance Min. 1 Mz 5 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.

Wiring harness between C01 (female) (17) – P04 (female) (2) Voltage Max. 1 V 6 Defective pump controller If causes 1 – 5 are not detected, pump controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)