UEN00242-00 40 Troubleshooting Failure code [DHS4MA] Bucket Curl PPC Press Sensor Abnormality 1 18 PC210, 230, 240-8 User code Failure code Trouble Bucket curl PPC pressure sensor abnormality (Pump controller system) — DHS4MA Contents of trouble • Signal voltage of bucket curl PPC pressure sensor circuit is below 0.3 V or above 4.5 V. Action of controller • Fixes bucket curl PPC pressure at 0 MPa {0 kg/cm2} and continues control. • If cause of failure disappears, system resets itself. Problem that appears on machine • Automatic decelerator cannot be reset. • Bucket curl performance lowers.
Related infor- mation a If 5V circuit (3) and ground circuit (1) of pressure sensor are connected inversely, pressure sensor will be broken. Accordingly, take extreme care when checking. • Bucket curl PPC pressure can be checked with monitoring function. (Code: 07300 Bucket curl PPC pressure) • Method of reproducing failure code: Turn starting switch ON or start engine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective 5V sensor power supply 1 system If failure code [DA25KP] is also displayed, carry out troubleshooting for it first.
2 Defective bucket curl PPC pressure sensor (Internal defect) a Prepare with starting switch OFF, then turn starting switch ON or start engine and carry out troubleshooting in each case. P01 Voltage Between (3) – (1) Power supply 4.5 – 5.5 V Between (2) – (1) Signal 0.3 – 4.5 V If voltage is abnormal, replace bucket curl PPC pressure sensor with another PPC pressure sensor and check failure code. (If "E" of failure code goes off at this time, bucket curl PPC pressure sensor is defective.) 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
Wiring harness between C01 (female) (18) – P01 (female) (1) Resis- tance Max. 1 z Wiring harness between C01 (female) (73) – P01 (female) (2) Resis- tance Max. 1 z Wiring harness between C01 (female) (9) – J06 – P01 (female) (3) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C01 (female) (73) – P01 (female) (2) Resis- tance Min. 1 Mz 5 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
Wiring harness between C01 (female) (73) – P01 (female) (2) Voltage Max. 1 V 6 Defective pump controller If causes 1 – 5 are not detected, pump controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)