Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DHS8MA] Boom Raise PPC Press Sensor Abnormality

UEN00242-00 40 Troubleshooting Failure code [DHS8MA] Boom Raise PPC Press Sensor Abnormality 1 20 PC210, 230, 240-8 User code Failure code Trouble Boom raise PPC pressure sensor abnormality (Pump controller system) — DHS8MA Contents of trouble • Signal voltage of boom raise PPC pressure sensor circuit is below 0.3 V or above 4.5 V. Action of controller • Fixes boom raise PPC pressure at 0 MPa {0 kg/cm2} and continues control. • If cause of failure disappears, system resets itself. Problem that appears on machine • Automatic decelerator cannot be reset. • Boom raise performance lowers.

Related infor- mation a If 5V circuit (3) and ground circuit (1) of pressure sensor are connected inversely, pressure sensor will be broken. Accordingly, take extreme care when checking. • Boom raise PPC pressure can be checked with monitoring function. (Code: 07400 Boom raise PPC pressure) • Method of reproducing failure code: Turn starting switch ON or start engine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective 5V sensor power supply 1 system If failure code [DA25KP] is also displayed, carry out troubleshooting for it first.

2 Defective boom raise PPC pressure sensor (Internal defect) a Prepare with starting switch OFF, then turn starting switch ON or start engine and carry out troubleshooting in each case. P06 Voltage Between (3) – (1) Power supply 4.5 – 5.5 V Between (2) – (1) Signal 0.3 – 4.5 V If voltage is abnormal, replace boom raise PPC pressure sensor with another PPC pressure sensor and check failure code. (If "E" of failure code goes off at this time, boom raise PPC pressure sensor is defective.) 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

Wiring harness between C01 (female) (18) – P06 (female) (1) Resis- tance Max. 1 z Wiring harness between C01 (female) (53) – P06 (female) (2) Resis- tance Max. 1 z Wiring harness between C01 (female) (9) – J06 – P06 (female) (3) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C01 (female) (53) – P06 (female) (2) Resis- tance Min. 1 Mz 5 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.

Wiring harness between C01 (female) (53) – P06 (female) (2) Voltage Max. 1 V 6 Defective pump controller If causes 1 – 5 are not detected, pump controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)