Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DHX1MA] Overload Sensor Abnormality (Analog)

UEN00242-00 40 Troubleshooting Failure code [DHX1MA] Overload Sensor Abnormality (Analog) 1 28 PC210, 230, 240-8 User code Failure code Trouble Overload sensor (analog) (Pump controller system) — DHX1MA Contents of trouble • Signal voltage of overload alarm pressure sensor circuit is below 0.3 V or above 4.4 V. Action of controller • Outputs overload alarm constantly. • If cause of failure disappears, system resets itself. Problem that appears on machine • If display of overload alarm monitor is set, overload alarm monitor is displayed constantly. Related infor- mation • Overload alarm pressure sensor is installed to only machine on which display of overload alarm monitor is set.

a If 5V circuit (3) and ground circuit (1) of pressure sensor are connected inversely, pressure sensor will be broken. Accordingly, take extreme care when checking. • Overload alarm pressure (Boom cylinder bottom pressure) can be checked with monitoring function. (Code: 15900 Boom bottom pressure) • Method of reproducing failure code: Turn starting switch ON or start engine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective 5V sensor power supply 1 system If failure code [DA25KP] is also displayed, carry out troubleshooting for it first.

2 Defective overload alarm pressure sensor (Internal defect) a Prepare with starting switch OFF, then turn starting switch ON or start engine and carry out troubleshooting in each case. P46 Voltage Between (3) – (1) Power supply 4.5 – 5.5 V Between (2) – (1) Signal 0.3 – 4.4 V If voltage is abnormal, replace overload alarm pressure sensor with F pump pressure sensor or R pump pressure sensor and check fail- ure code.

(If "E" of failure code goes off at this time, overload alarm pressure sensor is defective.) 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C01 (female) (18) – P46 (female) (1) Resis- tance Max. 1 z Wiring harness between C01 (female) (74) – P46 (female) (2) Resis- tance Max. 1 z Wiring harness between C01 (female) (9) – J06 – P46 (female) (3) Resis- tance Max.

1 z 4 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C01 (female) (9) – P46 (female) (2) Resis- tance Min. 1 Mz 5 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between C01 (female) (9) – P46 (female) (2) Voltage Max. 1 V 6 Defective pump controller If causes 1 – 5 are not detected, pump controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)