Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DW43KB] Travel Speed Sol Short

UEN00242-00 40 Troubleshooting Failure code [DW43KB] Travel Speed Sol Short 1 32 PC210, 230, 240-8 User code Failure code Trouble Travel speed solenoid system short (Pump controller system) — DW43KB Contents of trouble • When output to travel speed shifting solenoid was turned ON, short circuit was detected in circuit. Action of controller • Turns output to travel speed shifting solenoid OFF. • Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF. Problem that appears on machine • PC210: Speed is low at High travel speed position (Machine monitor is set to High but actual speed is about Middle). • PC240:

Speed is low at High and Middle travel speed position (Machine monitor is set to High or Middle but actual speed is about Low). Related infor- mation • Operating condition of travel speed shifting solenoid can be checked with monitoring function. (Code: 02300: Solenoid 1) • Method of reproducing failure code: Start engine + Set travel speed to High + Operate travel lever. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective travel speed shift- ing solenoid (Internal discon- nection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

V04 (male) Resistance Between (1) – (2) 20 – 60 z Between (1) – chassis ground Min. 1 Mz 2 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C02 (female) (87) – V04 (female) (1) Resis- tance Min. 1 Mz 3 Defective pump controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C02 (female) Resistance Between (87) – (115), (117), (120) 20 – 60 z Between (87) – chassis ground Min. 1 Mz