Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DW45KA] Swing Brake Sol Discon

UEN00242-00 40 Troubleshooting Failure code [DW45KA] Swing Brake Sol Discon 1 34 PC210, 230, 240-8 User code Failure code Trouble Swing holding brake solenoid system disconnection (Pump controller system) E03 DW45KA Contents of trouble • When output to swing holding brake solenoid was turned OFF, disconnection was detected in circuit. Action of controller • None in particular. (Since no current flows, solenoid does not operate.) • If cause of failure disappears, system resets itself. Problem that appears on machine • Machine cannot swing (Swing holding brake is not reset).

Related infor- mation • If solenoid and wiring harness are normal, operator can swing machine by setting swing holding brake release switch in release position (Swing holding brake does not work, however, when machine stops). • Keep swing lock switch in OFF position and swing holding brake release switch in release position during troubleshooting. • Operating condition of swing holding brake solenoid can be checked with monitoring function. (Code: 02300: Solenoid 1) • Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective swing holding brake solenoid (Internal dis- connection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. V03 (male) Resistance Between (1) – (2) 20 – 60 z 2 Defective assembled-type diode D01 (Internal discon- nection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

D01 (male) Digital circuit tester Continuity Between (7) – (3) Diode mode There is continuity 3 Defective swing lock switch (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. S04 (male) Swing lock switch Resistance Between (3) – (4) OFF Max. 1 z ON Min. 1 Mz 4 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C02 (female) (101) – D01 (female) (7) Resis- tance Max.

1 z Wiring harness between D01 (female) (3) – J02 – S04 (female) (3) Resis- tance Max. 1 z Wiring harness between S04 (female) (4) – V03 (female) (1) Resis- tance Max. 1 z Wiring harness between C02 (female) (115), (117), (120) – V03 (female) (2) Resis- tance Max. 1 z 5 Defective pump controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C02 (female) Disconnect D01 and connect pins (3) and (7) on female side directly. Resistance Between (101) – (115), (117), (120) 20 – 60 z