UEN00242-00 40 Troubleshooting Failure code [DW91KA] Travel Junction Sol Discon 1 38 PC210, 230, 240-8 User code Failure code Trouble Travel junction solenoid system disconnection (Pump controller system) — DW91KA Contents of trouble • When output to travel junction solenoid was turned ON, disconnection was detected in circuit. Action of controller • None in particular. (Since no current flows, solenoid does not operate.) • If cause of failure disappears, system resets itself. Problem that appears on machine • Machine is not steered easily during travel. Related infor- mation • Operating condition of travel junction solenoid can be checked with monitoring function. (Code:
02300 Solenoid 1) • Method of reproducing failure code: Start engine + Steer machine with right and left travel levers. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective travel junction solenoid (Internal disconnec- tion) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. V05 (male) Resistance Between (1) – (2) 20 – 60 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
Wiring harness between C02 (female) (110) – V05 (female) (1) Resis- tance Max. 1 z Wiring harness between C02 (female) (115), (117), (120) – V05 (female) (2) Resis- tance Max. 1 z 3 Defective pump controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C02 (female) Resistance Between (110) – (115), (117), (120) 20 – 60 z